products: Views:9Three-phase rectifier bridge module MDS300A-16 
brand: 德邦
过载电流: 300A
过载电压: 1600V
price: 135.00元/支
MOQ: 1 支
Total supply: 100000 支
Delivery date: Shipped within 1 days from the date of payment by the buyer
Valid until: 2017-06-11 [Expired]
Last updated: 2016-06-11 15:20
Details
use and maintenance personnel must understand the principles, performance, usage and precautions of the product. To avoid device damage and economic losses caused by improper use. . When selecting the current and voltage, an appropriate margin should be left and should not be too large or too small.
. There must be overcurrent protection measures in the line. When used in series and parallel, voltage equalization and current equalization measures must be taken.
Please handle with care during transportation, storage and use.
, When assembling the module by yourself
)
The cooling effect of your own radiator must be verified through tests to meet your needs
)
The radiator table needs to be cleaned< br/> )
Coat the table with thermally and electrically conductive silicone grease (paste)
You can use a multimeter to simply judge whether the device is damaged:
)
The resistance between the gate and the cathode should be more than ten or more Dozens otherwise the gate is short-circuited or open-circuited.
)
The resistance between cathode and anode should be greater than (except the forward direction of the rectifier). If the resistance is less than the table, the insulation performance between the device's electrodes is poor. When the resistance is close to zero, it indicates that the device has broken down.
Products with quality problems identified by our company are guaranteed to be returned or replaced. You must bring the original product certificate when returning or exchanging.
Environment
Environment
Conditions

,
Self-cooling and air-cooling ambient temperature - ℃ ~ ℃ Water cooling ambient temperature ℃ ~ ℃
,
Air relative temperature %
,
There is no corrosive gas and dust that damages insulation in the air
,
Air pressure~
,
No violent Vibration or impact
,
If there are special occasions, corresponding tests should be carried out to prove that the work is reliable before use.
Cooling conditions
,
Forced air cooling: wind speed/
Air temperature

, Water cooling: flow rate/pressure
. Water temperature ℃ water Resistivity value
Other cooling methods should be used after corresponding tests to prove their reliability.
Installation and Use Instructions
The ambient temperature when using the module shall not be higher than ℃. When it is higher than ℃, it should be derated. Humidity must not be higher than %.
In the device, the module should be placed in a location where heat is easy to dissipate and the wind flow is smooth. The wind speed should not be less than /. When the wind speed is low or when self-cooling is used, the cooling module should be derated and used. No matter what kind of cooling module is used, the cooling module must not exceed the shell temperature. The measuring point of the shell temperature is the geometric center of the long side bottom plate of the module.
The surface of the radiator on which the module is installed must be flat, smooth and free of scratches. During installation, surface contamination must be removed and a layer of thermally conductive silicone grease (oil) such as type thermal grease must be applied. This can effectively reduce the contact thermal resistance and reduce the shell temperature, which is beneficial to the safe operation of the module. The tightening torque of the mounting bolts is + and verify that the module bottom plate is in close contact with the radiator table. Connect correctly according to the instructions on the template label and the electrode markings on the shell. The tightening torque of the wiring screws is +~ and the contact between the wires and the electrodes is good to reduce heat generation.